100 ohm differential impedance recommended design
line width, spacing 5/7/5mil differential pair and the distance between the pair ≥ 14mil (3W criterion);
Note: It is recommended that the entire group of differential signal lines is shielded with ground, and the distance between the differential signal and the shielded ground line is ≥35mil (in special cases, it cannot be less than 20mil).
90 ohm differential impedance recommended design
line width, spacing 6/6/6mil differential pair, and the distance between the pair ≥12mil (3W criterion).
Note: In the case of a long differential pair trace, it is recommended that the USB differential line wrap the ground at a distance of 6 mils on both sides to reduce the risk of EMI (with and without ground, the line width and line spacing standards are consistent).

Calculation parameters:
FR-4, thickness 1.6mm+/-10%, dielectric constant 4.4+/-0.2, copper thickness 1.0 oz (1.4mil), copper clad substrate(PP) 2116 (4.0-5.0mil), dielectric constant 4.3+/-0.2, solder mask thickness 0.6±0.2mil, dielectric constant 3.5+/-0.3.
Stack-up:
Solder mask
Copper
Prepreg
Base material
Prepreg
Copper
Solder mask
Silkscreen