Routing Rules of BGA package in PCB design

Types of BGA Parts

The small parts that usually surround the BGA can be divided into several categories according to the priority of importance:

  1. by pass.
  2. Clock terminal RC circuit.
    (appears in series resistance, row group type; such as memory BUS signal)
  3. EMI RC circuit (appears as dampin, C, pull height; eg USB signal).
  4. Other special circuits (special circuits added according to different CHIPs; such as CPU temperature sensing circuits).
  5. Small power supply circuit group below 40mil (appears in the form of C, L, R, etc. This kind of circuit often appears near the AGP CHIP or CHIP with AGP function, and separates different power supply groups through R and L).
  6. Pull low R, C.
  7. General small circuit group (appears in the form of R, C, Q, U, etc.; no wiring requirements).
  8. pull height R, RP.

Routing Rules for BGA Package

The circuits of items 1-6 are usually the focus of placement and will be arranged as close to the BGA as possible, which requires special treatment. Item 7 is the second most important circuit, but it will also be placed closer to the BGA.
Relative to the priority of the importance of small parts near the BGA above, the requirements on ROUTING are as follows: 

1. by pass

 When it is on the same side as CHIP, directly connect the CHIP pin to the by pass, and then pull it out from the by pass and connect it to the plane; when it is on a different side from the CHIP, it can share the same via with the VCC and GND pins of the BGA, The line length should not exceed 100ml.

2. Clock terminal RC circuit

the requirements of line width, line spacing, line length or including GND; the wiring should be as short and smooth as possible, and try not to cross the VCC separation line.

3. damping

Wire width, wire spacing, wire length, and grouped wiring are required; the wiring should be as short and smooth as possible, and the wiring should not be mixed with other signals.

4. EMI RC circuit

line width, line spacing, parallel lines, GND package, etc. (according to customer requirements.)

5. Other special circuits

Wire width, GND package or wiring clearance and other requirements; according to customer requirements.

6. Small power circuit group below 40mil

wire width and other requirements; try to complete it with the surface layer, reserve the inner space completely for the signal line, and try to avoid the power signal passing through the upper and lower layers in the BGA area, causing unnecessary interference.

7. pull low R, C

no special requirements; smooth wiring.